Spennymoor

GSPNPGNGET400 kV132 kV66 kV20 kV

At a glance

Generation Locked Sources retrieved 7 Oct 2026
Generation headroom
██.█MW
Spennymoor 132 kV. NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Demand headroom
██.█MW
Spennymoor 132 kV. NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Fault level
██.█kA
Spennymoor 132 kV. NPG LTDS Appendix 6 Fault Level Data
Firm capacity
██.█MVA
Spennymoor 132 kV. NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026

Highest figure across the site's 9 busbars; fault level is the busbar nearest its break rating. Each busbar is listed below.

Location

54.70514, -1.55123

From DNO data
Directions (Google Maps, new tab)

Connection queue

NESO TEC Register (live, archive datastore dump); NPG Embedded Capacity Register (>=1 MW) and 1 more, retrieved 7 Oct 2026

Queued
██.█MW
Connected
██.█MW
Projects
22
Unlock the full 22-project queue with a premium subscription

132 kV

2 busbars

Spennymoor_NPg 132 kV

NPGdistribution

No capacity or fault data published for this busbar

Spennymoor 132 kV

NPG Generation Lockeddistribution
Generation headroom
██.█MW
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Demand headroom
██.█MW
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Firm capacity
██.█MVA
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Fault level (3-phase)
██.█kA
NPG LTDS Appendix 6 Fault Level Data
Fault and rating detail
Fault level (1-phase)
██.█kA
Make rating
██.█kA
Break rating
██.█kA

66 kV

2 busbars

Spennymoor_NPg 66 kV

NPGdistribution

No capacity or fault data published for this busbar

Spennymoor 66 kV

NPG Generation Lockeddistribution
Generation headroom
██.█MW
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Demand headroom
██.█MW
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Firm capacity
██.█MVA
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Fault level (3-phase)
██.█kA
NPG LTDS Appendix 6 Fault Level Data
Fault and rating detail
Make rating
██.█kA
Break rating
██.█kA

20 kV

2 busbars

Spennymoor_NPg 20 kV

NPGdistribution

No capacity or fault data published for this busbar

Spennymoor 20 kV

NPG Generation Lockeddistribution
Generation headroom
██.█MW
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Demand headroom
██.█MW
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Firm capacity
██.█MVA
NPG Heat Map Data - Table (firm, demand, headroom), retrieved 27 Sep 2026
Fault level (3-phase)
██.█kA
NPG LTDS Appendix 6 Fault Level Data
Fault and rating detail
Make rating
██.█kA
Break rating
██.█kA

Other voltage levels

  • 400 kVSpennymoor 400 kV NGETNot openly published by NESO
  • Voltage not statedSpennymoor NGETNot openly published by NESO
  • Voltage not statedSPENNYMOOR GRID NPGNo capacity or fault data published for this busbar

Planned reinforcement

1 scheme, first in service 2027DNO Network Development Reports
SchemeDriverUpliftIn service
Replacement of 66kV circuit breakersCondition+0.0 MVA2027

Data source

Distribution operator: Northern Powergrid. Licence: Northern Powergrid Open Data Licence v1.0

Transmission owner: National Grid Electricity Transmission. Licence: NESO Open Data Licence

Supported by Northern Powergrid Open Data Supported by National Energy SO Open Data Office for National Statistics licensed under the Open Government Licence v.3.0 Contains OS data © Crown copyright and database right [2019-]

Derived from publicly available DNO and TSO datasets: we cluster, merge and calculate from the published records, so these figures are modified from the source. Indicative only; verify directly with the operators before making connection decisions. Attribution and licences