Taynuilt

GSPSSENSSEN_TX132 kV33 kV11 kV

At a glance

Generation headroom, free

Red

No headroom

Source SSEN Headroom Dashboard Data, March 2026, retrieved 27 Sep 2026Highest of 4 busbarsBand free, exact MW with Pro

Other figures

Sources retrieved 17 Oct 2026
Demand headroom
██.█MVA
TAYNUILT 11 kV. SSEN Headroom Dashboard Data, March 2026, retrieved 27 Sep 2026
Fault level
██.█kA
TAYNUILT SUBSTATION. SSEN Transmission ETYS 2025 Year 1 (2025/26) Fault Levels, Winter
Firm capacity
██.█MVA
TAYNUILT 11 kV. SSEN LTDS Table 3 firm capacity (SEPD + SHEPD, newest edition), retrieved 27 Sep 2026

Highest figure across the site's 4 busbars; fault level is the busbar nearest its break rating. Each busbar is listed below.

Fault level near your switchgear rating? Star Delta Power does the study.

Location

56.43039, -5.21426

From DNO data
Directions (Google Maps, new tab)

Connection queue

NESO TEC Register (live, archive datastore dump); SSEN ECR Part 1, 1 MW and 50 kW registers (files), retrieved 17 Oct 2026

Queued
274 MW
Connected
61 MW
Projects
32
See the 32 projects behind this queue with Pro

132 kV

1 busbar

TAYNUILT SUBSTATION

SSEN_TXtransmission Source (opens the operator's dataset in a new tab)
Fault level (3-phase)
██.█kA
SSEN Transmission ETYS 2025 Year 1 (2025/26) Fault Levels, Winter

Not published for this busbar: generation headroom, demand headroom, firm capacity.

Fault and rating detail
Fault level (1-phase)
██.█kA

33 kV

1 busbar

TAYNUILT 33 kV

SSEN Generation Lockeddistribution
Fault level (3-phase)
██.█kA
SHEPD LTDS Tables 1-7, May 2026

Not published for this busbar: generation headroom, demand headroom, firm capacity.

Fault and rating detail
Break rating
██.█kA

11 kV

1 busbar

TAYNUILT 11 kV

SSEN Generation Lockeddistribution
Generation headroom
██.█MW
SSEN Headroom Dashboard Data, March 2026, retrieved 27 Sep 2026
Demand headroom
██.█MVA
SSEN Headroom Dashboard Data, March 2026, retrieved 27 Sep 2026
Firm capacity
██.█MVA
SSEN LTDS Table 3 firm capacity (SEPD + SHEPD, newest edition), retrieved 27 Sep 2026
Fault level (3-phase)
██.█kA
SHEPD LTDS Tables 1-7, May 2026
Fault and rating detail
Make rating
██.█kA
Break rating
██.█kA

Other voltage levels

  • Voltage not statedTaynuilt SSEN_TXNo capacity or fault data published for this busbar

Planned reinforcement

2 schemes, first in service 2025DNO Network Development Reports
SchemeDriverUpliftIn service
Demand reinforcement at Taynuilt (NSHR expected in-service date 2025)Capacity2025
Generation reinforcement at Taynuilt (NSHR expected in-service date 2034)Capacity2034

Data source

Distribution operator: Scottish and Southern Electricity Networks. Licence: CC BY 4.0

Transmission owner: Scottish and Southern Electricity Networks Transmission. Licence: CC BY 4.0

SSEN Transmission is a trading name of Scottish Hydro Electric Transmission plc, company number SC213461

Derived from publicly available DNO and TSO datasets: we cluster, merge and calculate from the published records, so these figures are modified from the source. Indicative only; verify directly with the operators before making connection decisions. Attribution and licences